| Technical Data |
|
| Design |
Angular |
| Based on standard |
EN 60947-5-2VDI/VDE 3845 |
| Approval |
RCM trademarkc UL us - Recognized (OL) |
| CE mark (see declaration of conformity) |
To EU EMC DirectiveIn accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) |
To UK instructions for EMCTo UK RoHS instructions |
| KC mark |
KC-EMV |
| Certificate issuing authority |
UL E232949 |
| Note on materials |
RoHS-compliant |
| Measuring principle |
Inductive |
| Ambient temperature |
-2570 |
| Switching output |
PNP |
| Switching element function |
N/O contact |
| Max. switching frequency |
1000 |
| Max. output current DC |
200 |
| Voltage drop |
2.5 |
| Off-state current |
00.5 |
| Short circuit current rating |
Pulsed |
| Operational voltage range DC |
1030 |
| No-load supply current |
22.5 |
| Reverse polarity protection |
For all electrical connections |
| Electrical connection input |
PlugsM12x14-pin |
| Mounting position |
optional |
| Product weight |
48 |
| Material housing |
PBT |
| Material screws |
High-alloy stainless steel |
| Ready status indication |
Green LED |
| Switching status indication |
Yellow LED |
| Status indication |
LED yellow = valve switching statusLED green = power supply indicator |
| Storage temperature |
-4085 |
| Degree of protection |
IP67 |
| Shock resistance |
Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Vibration resistance |
Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| LABS (PWIS) conformity |
VDMA24364 zone III |
| Pollution degree |
3 |