| Technical Data |
|
| Valve function |
5/3 closed |
| Type of actuation |
Electric |
| Construction width |
32 |
| Standard nominal flow rate (standardised to DIN 1343) |
1250 |
| pneumatic working port |
NAMUR port pattern |
| Operating voltage |
Via solenoid coil, must be ordered separately |
| Operating pressure |
38 |
| Design |
Piston gate valve |
| Type of reset |
Mechanical spring |
| Certificate issuing authority |
DNVGL-TAA000011J |
| Exhaust-air function |
With flow control option |
| Sealing principle |
Soft |
| Mounting position |
optional |
| Conforms to standard |
VDI/VDE 3845 (NAMUR) |
| Manual override |
DetentingNon-detenting |
| Type of piloting |
Pilot actuated |
| Pilot air supply |
Internal |
| Flow direction |
Non-reversible |
| Symbol |
00991080 |
| lap |
Overlap |
| Signal status display |
With accessories |
| b value |
0.4 |
| C value |
5.2 |
| Switching time off |
103 |
| Switching time on |
23 |
| Switching time reversal |
55 |
| Duty cycle |
100% |
| Characteristic coil data |
See solenoid coil, to be ordered separately |
| Operating medium |
Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium |
Lubricated operation possible (in which case lubricated operation will always be required) |
| Corrosion resistance class CRC |
2 - Moderate corrosion stress |
| LABS (PWIS) conformity |
VDMA24364-B2-L |
| Media temperature |
-2060 |
| Ambient temperature |
-2060 |
| Product weight |
450 |
| Type of mounting |
With through-hole |
| Breather connection |
Not ducted |
| Pneumatic connection, port 1 |
G1/4 |
| Pneumatic connection, port 2 |
NAMUR port pattern |
| Pneumatic connection, port 3 |
G1/4 |
| Pneumatic connection, port 4 |
NAMUR port pattern |
| Pneumatic connection, port 5 |
G1/4 |
| Note on materials |
RoHS-compliant |
| Material seals |
NBR |
| Material housing |
Wrought aluminium alloy |
| Material screws |
Galvanised steel |