Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

DTI431 – фото
DTI431 – фото
DTI431 – фото
Фото
Видео

На DTI431

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Operating frequency 13,56
Communication interface IO-Link
Dimensions M30 x 1.5 / L = 50
Product designation Read/write antenna
Radio approval for USA, Canada, EU/RED, Australia, Japan, China, Taiwan, India, Singapore, South Korea

Все характеристики

Application
Application Detection of objects on transport equipment
Radio approval for USA; Canada; EU/RED; Australia; Japan; China; Taiwan; India; Singapore; South Korea
Note on radio approval <table><tr><td>The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”. </td></tr></table>
Electrical data
Operating voltage 19.2...28.8 DC
Current consumption < 50
Protection class III
Operating frequency 13,56
RFID standard ISO 15693
Monitoring range
Distance write/read head front 160
Distance write/read head side 120
Distance to the ID tag <table><tr><td>referred to 30 mm coin tag; I-CODE SLI</td><td>:</td><td>≤ 45</td></tr></table>
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr></table>
SIO mode no
Required master port class A
Min. process cycle time 22
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>967</td></tr></table>
Operating conditions
Ambient temperature -20...60
Storage temperature -25...80
Protection IP 67; IP 69K
Tests / approvals
Shock resistance <table><tr><td>EN 60068-2-27</td><td>40 g 6 ms / repetitive</td></tr><tr><td>EN 60068-2-27</td><td>50 g 11 ms / not repetitive</td></tr></table>
Vibration resistance <table><tr><td>EN 60068-2-6</td><td>20 g 10...2000 Hz</td></tr></table>
MTTF 559
UL approval <table><tr><td>Ta</td><td>-20...60 °C</td></tr><tr><td>Enclosure type</td><td>Type 1 </td></tr><tr><td>voltage supply</td><td>Limited Voltage/Current </td></tr><tr><td>File number UL</td><td>E205959 </td></tr></table>
Mechanical data
Weight 178.5
Housing Threaded type
Mounting non-flush mountable
Dimensions M30 x 1.5 / L = 50
Thread designation M30 x 1.5
Material housing: stainless steel; Protective cover: PPS
Displays / operating elements
Display <table><tr><td>Power</td><td>1 x LED, green</td></tr><tr><td>tag communication</td><td>1 x LED, yellow</td></tr></table>
Accessories
Items supplied <table><tr><td>lock nuts: 2 x M30</td></tr></table>
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A

Приемущества

For the reliable identification of ID tags on workpiece carriers and products
Robust stainless steel housing for applications in mounting, feeding and handling technology
High protection rating for the requirements of harsh industrial environments
RFID read/write head HF for non-flush mounting
For connection to IO-Link master version 1.1 by means of industry standard M12 connection