Характеристики

IO-Link revision 1.1
Communication interface IO-Link, AS-i
Protection IP 65, IP 66, IP 67
Product designation IO-Link master StandardLine

Все характеристики

Application field installation
Daisy-chain function voltage supply; fieldbus interface
Operating voltage 18...31.6 DC; (AS-i)
Current consumption 300...1500; (AUX)
Max. current consumption from AS-i 100
Protection class III
Max. current load total 1.1; (ports 1+2: 0,55 (AUX); ports 3+4: 0,55 (AUX))
Additional voltage supply 20...30 DC; (AUX)
Total number of inputs and outputs 8; (configurable)
Number of inputs and outputs Number of digital inputs: 8; Number of digital outputs: 4
Number of digital inputs 8; (IO-Link Port Class A: 4 x 2)
Sensor supply of the inputs AUX
Switching level high 11...30
Switching level low 0...5
Digital inputs protected against short circuits yes
Number of digital outputs 4; (IO-Link Port Class A: 4 x 1)
Max. current load per output 300
Short-circuit proof yes
Actuator supply outputs AUX
Communication interface IO-Link; AS-i
Transmission type COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud)
IO-Link revision 1.1
Number of ports class A 4
Ambient temperature -25...60
Storage temperature -25...85
Max. relative air humidity 90
Protection IP 65; IP 66; IP 67
Protection rating (NEMA 250) 6P
Degree of soiling 2
Chemical media
ISO 16750-5AA, BA, BD, HLP, CC, DB, DC, DD, CA
NEMA 250 5.13.1AA
EMC
EN 61000-6-2
EN 61000-6-4
Shock resistance
DIN EN 60068-2-27
Vibration resistance
DIN EN 60068-2-64 2009-04
DIN EN 60068-2-6 2008-10
MTTF 161
AS-i version 2.11; 3.0
Extended addressing mode no
AS-i profile
basic slave (CTT1 input)S-7.4.E
additional slave (CTT1 input)S-7.3.E
additional slave (CTT1 output)S-7.3.2
Number of AS-i devices 1...5
Weight 247
Housing rectangular
Type of mounting Backplane mounting
Dimensions 124 x 59.3 x 38.4
Material housing: PA orange; Socket: brass nickel-plated
Module connection M12
Remarks
Further information is available in the manual.
Pack quantity 1 pcs.
IO-Link Port Class A X01...X04 Connector: 4 x M12; coding: A
X21 Connector: 1 x M12; coding: A
X22 Connector: 1 x M12; coding: A

Приемущества

Reliable transmission of machine data, process parameters and diagnostic data to the controller
Simple replacement of units due to integrated parameter memory
Robust housing for use in harsh industrial environments
For connection of up to four IO-Link devices