AL1402 – фото
AL1402 – фото
Фото
Видео

На AL1402

Для заявки пишите в МАХ или Telegram

# #

Характеристики

IO-Link revision 1.1
Communication interface IO-Link, PROFINET
Protection IP 65, IP 66, IP 67
Product designation IO-Link master PerformanceLine

Все характеристики

Application I/O modules for field applications
Daisy-chain function voltage supply; fieldbus interface
Operating voltage 20...30 DC; (US ; to PELV)
Current consumption 300...3900; (US)
Protection class III
Additional voltage supply 20...30 DC; (UA)
Max. current load per output 2000
Max. current load per output 2000
Total number of inputs and outputs 16; (configurable)
Number of inputs and outputs Number of digital inputs: 12; Number of digital outputs: 12
Number of digital inputs 12; (IO-Link Port Class A: 4 x 2; IO-Link Port Class B: 4 x 1)
Switching level high 11...30
Switching level low 0...5
Digital inputs protected against short circuits yes
Number of digital outputs 12; (IO-Link Port Class A: 4 x 1; IO-Link Port Class B: 4 x 2)
Short-circuit proof yes
Communication interface Ethernet; IO-Link
Transmission standard 100Base-TX
Transmission rate 100 MBit/s
Protocol PROFINET
Factory settings
IP address: 0.0.0.0
subnet mask: 0.0.0.0
gateway IP address: 0.0.0.0
MAC address: see type label
Note on interfaces
IO-Link Integration Edition 2
CC-C (Conformance Class C) (IRT-Switch)
S2 redundancy
Netload Class III
CiR (Configuration in Run)
SNMP (Simple Network Management Protocol)
MRP (Media Redundancy Protocol)
Supported network topologies: line
ring
Transmission type COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud)
IO-Link revision 1.1
Number of ports class A 4
Number of ports class B 4
Ambient temperature -25...60
Storage temperature -25...85
Max. relative air humidity 90
Protection IP 65; IP 66; IP 67
Protection rating (NEMA 250) 6P
Degree of soiling 2
Chemical media
ISO 16750-5AA, BA, BD, HLP, CC, DB, DC, DD, CA
NEMA 250 5.13.1AA
EMC
EN 61000-6-2
EN 61000-6-4
Shock resistance
DIN EN 60068-2-27
Vibration resistance
DIN EN 60068-2-64 2009-04
DIN EN 60068-2-6 2008-10
MTTF 43
Weight 412.1
Housing rectangular
Type of mounting Backplane mounting
Dimensions 208 x 59.3 x 38.4
Material housing: PA orange; Socket: brass nickel-plated
Sealing material FKM
Remarks
Further information is available in the manual.
Pack quantity 1 pcs.
IN / OUT XF1, XF2 Connector: 2 x M12; coding: D; sealing: FKM
IO-Link Port Class B X1...X4 Connector: 8 x M12; coding: A; sealing: FKM
XD1 Connector: 1 x M12; coding: L
XD2 Connector: 1 x M12; coding: L; sealing: FKM

Приемущества

Daisy-chain power supply with standardized L-coded M12 connection technology
Configurable current limitation for each port to ensure safe operation
Voltage and current measurement per port for energy monitoring
Connection of actuators up to 2 A
IO-Link master developed according to AIDA specifications of the automotive manufacturers