| Number of inputs and outputs |
Number of digital inputs: 8; Number of pneumatic outputs: 2 |
| Design |
housing for DIN rail mounting |
| Application |
field installation; for use in wet environments |
| Media |
compressed air |
| Medium temperature |
-10...50 |
| Operating voltage |
18...30 DC; (to SELV/PELV) |
| Nominal voltage DC |
24 |
| Current consumption |
80...680; (24 V DC, full load) |
| Overvoltage category |
II |
| Number of inputs and outputs |
Number of digital inputs: 8; Number of pneumatic outputs: 2 |
| Number of digital inputs |
8; (4 x 2) |
| Input circuit of digital inputs |
PNP |
| Sensor supply of the inputs |
US |
| Voltage supply |
18...30; (from the operating voltage) |
| Max. total current rating of inputs |
400 |
| Input current High |
2...3.5 |
| Input current low |
0...1.5 |
| Switching level high |
> 11 |
| Digital inputs protected against short circuits |
yes |
| Number of pneumatic outputs |
2 |
| Actuator supply outputs |
US |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
| Common - I&D | Identification and Diagnosis | | Function | Locator | | Function | ProductURI |
|
| SIO mode |
no |
| Required master port class |
A |
| Min. process cycle time |
2.7 |
| Supported DeviceIDs |
| Type of operation | DeviceID |
|---|
| default | 1506 |
|
| Ambient temperature |
-10...55 |
| Note on ambient temperature |
| Switching frequency < 1,66 Hz: -10...50 °C | | Switching frequency > 1,66 Hz: -10...55 °C |
|
| Max. relative air humidity |
90; (non condensing) |
| Max. height above sea level |
4000 |
| Protection |
IP 65; IP 67 |
| Degree of soiling |
2 |
| Weight |
272 |
| Housing |
rectangular |
| Type of mounting |
Mounting on DIN rail; quick mounting; AS-i flat cable connection; (TH35 (EN 60715)) |
| Dimensions |
109 x 85 x 52 |
| Material |
housing: PA 6.6; AirBox housing: PA 6; sealing: TPE; sealing rings: NBR |
| Pneumatic system |
1 x 5/3-way slide valve (free from overlapping); middle position blocked |
| Operating pressure range |
|
| Air flow at 6/5 bar |
500 |
| Permissible compressed air |
non-lubricated compressed air class 6-3-1; lubricated compressed air class 6-3-4 |
| Manual override |
pressing/releasing or pressing/turning/locking |
| Tube fittings |
8 mm |
| Exhaust |
exhaust can be discharged through tube connection |
| Display |
| Power | LED, green | | errors | LED, red | | Function | LED, yellow |
|
| Items supplied |
|
| Accessories (optional) |
| Mounting plate:, E74999 | | Module lower part:, E75000 | | Protective cap: M12, E73004 | | sealing plug:, E75231 | | Silencer:, E75232 | | Push-in L-fitting:, E75228 | | Push-in T-fitting:, E75227 |
|
| Remarks |
| If not pneumatically operated, E75231 sealing plug must be inserted. | | Avoid ingress of dirt and dust. | | Do not connect any of the following points to an external potential: | | L-, L+, I-1, I-2, I-3, I-4 | | Please see the notes on compressed air and EMC/ESD under "Downloads" |
|
| Pack quantity |
1 pcs. |
| Digital input X1.0...X1.3 |
Connector: 4 x M12; coding: A |
| voltage supply X1 |
Connector: 1 x M12; coding: A |