Характеристики

Output function normally open / closed; (configurable); analog
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; FKM
Measuring range 1.5...396
Electrical design PNP/NPN
Process connection G 1/2 external thread DN15

Все характеристики

Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
1.5...396 gph0.03...6.6 gpm
Process connection threaded connection G 1/2 external thread DN15 flat seal
System gold-plated contacts
Application Totalizer function; for industrial applications
Installation connection to pipe by means of an adapter
Media Conductive liquids; water; water-based media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature 14...158
Pressure rating
16 bar232 psi1.6 MPa
MAWP (for applications according to CRN)
15.3 bar1.53 MPa
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption 95; (24 V)
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time 5
Measuring principle magnetic-inductive
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Inputs counter reset
Total number of outputs 2
Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 200
Number of analog outputs 1
Analog current output 4...20; (scalable)
Max. load 500
Analog voltage output 0...10; (scalable)
Min. load resistance 2000
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring range
1.5...396 gph0.03...6.6 gpm
Display range
-475.5...475.5 gph-7.925...7.925 gpm
Resolution
0.5 gph0.01 gpm
Set point SP
3.5...396.5 gph0.06...6.6 gpm
Reset point rP
1.5...394 gph0.03...6.57 gpm
Analog start point ASP
0...318 gph0...5.3 gpm
Analog end point AEP
78...396 gph1.3...6.6 gpm
In steps of
0.5 gph0.01 gpm
Pulse value 0.01...30 000 000 gal
Pulse length 0,01...2
Dynamic response T05 / T09 T09 = 20 (Q > 0,26 gpm)
Response time 0.15; (dAP = 0, T19)
Delay time programmable dS, dr 0...50
Damping process value dAP 0...5
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice identification
FunctionProcess data variable
FunctionDevice diagnosis
SIO mode yes
Required master port class A
Process data analog 3
Process data binary 2
Min. process cycle time 5
Supported DeviceIDs
Type of operationDeviceID
default570
Ambient temperature 14...140
Storage temperature -13...176
Protection IP 67
EMC
DIN EN 60947-5-9
Shock resistance
DIN IEC 68-2-2720 g (11 ms)
Vibration resistance
DIN IEC 68-2-65 g (10...2000 Hz)
MTTF 160
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight 546
Housing tubular
Dimensions Ø 54 / L = 110
Material stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; FKM
Process connection threaded connection G 1/2 external thread DN15 flat seal
Display
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
Switching status2 x LED, yellow
Measured valuesalphanumeric display, 4-digit
Programmingalphanumeric display, 4-digit
Remarks
MW = Measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
With switching output, analog output and pulse output
Clearly visible numerical display