| Number of inputs and outputs |
Number of analog outputs: 1 |
| Measuring range |
0.2...100 |
| Process connection |
threaded connection G 1 external thread DN25 flat seal |
| System |
gold-plated contacts |
| Application |
for industrial applications |
| Installation |
connection to pipe by means of an adapter |
| Media |
Conductive liquids; water; water-based media |
| Note on media |
| conductivity: ≥ 20 µS/cm | | viscosity: < 70 mm²/s (40 °C) |
|
| Medium temperature |
-10...70 |
| Pressure rating |
|
| MAWP (for applications according to CRN) |
|
| Operating voltage |
18...30 DC; (to SELV/PELV) |
| Current consumption |
95; (24 V) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
5 |
| Measuring principle |
magnetic-inductive |
| Number of inputs and outputs |
Number of analog outputs: 1 |
| Total number of outputs |
1 |
| Output signal |
analog signal; IO-Link; (configurable) |
| Permanent current rating of switching output DC |
250 |
| Number of analog outputs |
1 |
| Analog current output |
4...20 |
| Max. load |
500 |
| Overload protection |
yes |
| Measuring range |
0.2...100 |
| Response time |
0.15; (dAP = 0, T19) |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
| Smart Sensor - SSP 0 | Generic Profiled Sensor | | Function | Device identification | | Function | Process data variable | | Function | Device diagnosis |
|
| SIO mode |
yes |
| Required master port class |
A |
| Process data analog |
2 |
| Min. process cycle time |
5 |
| Supported DeviceIDs |
| Type of operation | DeviceID |
|---|
| default | 577 |
|
| Ambient temperature |
-10...60 |
| Storage temperature |
-25...80 |
| Protection |
IP 67 |
| EMC |
|
| CPA approval |
| model number | 002MI | | accuracy class | - | | maximum allowable error | ± 1,5 % FS | | Q (min) | 0,01 m³/h | | Q (t) | - | | Q (max) | 6 m³/h |
|
| Shock resistance |
| DIN IEC 68-2-27 | 20 g (11 ms) |
|
| Vibration resistance |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
|
| MTTF |
167 |
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight |
575 |
| Housing |
tubular |
| Dimensions |
Ø 54 / L = 110 |
| Material |
stainless steel (1.4404 / 316L); PBT-GF20; FKM; TPE |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); PEEK; FKM |
| Process connection |
threaded connection G 1 external thread DN25 flat seal |
| Remarks |
| MW = Measured value | | MEW = Final value of the measuring range |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |