| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range |
|
| Process connection |
threaded connection G 3/4 external thread flat seal |
| System |
gold-plated contacts |
| Application |
Totalizer function; for industrial applications |
| Installation |
connection to pipe by means of an adapter |
| Media |
water; glycol solutions; Coolants; oils |
| Note on media |
| low-viscosity oils with viscosity: 7...40 mm²/s (40 °C) | | high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
|
| Medium temperature |
-10...80 |
| Pressure rating |
|
| Operating voltage |
19...30 DC; (to SELV/PELV) |
| Current consumption |
100 |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
10 |
| Measuring principle |
ultrasonic |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Inputs |
counter reset |
| Total number of outputs |
2 |
| Output signal |
switching signal; analog signal; pulse signal; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC |
2 |
| Permanent current rating of switching output DC |
250; (per output) |
| Number of analog outputs |
1 |
| Analog current output |
4...20; (scalable) |
| Max. load |
500 |
| Analog voltage output |
0...10; (scalable) |
| Min. load resistance |
2000 |
| Pulse output |
flow rate meter |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring range |
|
| Display range |
|
| Resolution |
|
| Set point SP |
| 0.1...50 l/min | 0.005...3 m³/h |
|
| Reset point rP |
| 0...49.9 l/min | 0...2.995 m³/h |
|
| Analog start point ASP |
|
| Analog end point AEP |
| 10...50 l/min | 0.6...3 m³/h |
|
| Max. flow rate |
|
| In steps of |
|
| Pulse value |
0.1 l...1 000 000 m³ |
| Pulse length |
0,05...2 |
| Dynamic response T05 / T09 |
T09 = 70 (Q > 5 l/min); (water) |
| Response time |
0.25; (dAP = 0) |
| Delay time programmable dS, dr |
0...50 |
| Damping process value dAP |
0...1 |
| Parameter setting options |
Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
| Ambient temperature |
-10...60 |
| Storage temperature |
-25...80 |
| Protection |
IP 67 |
| EMC |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-5 Surge | 0,5 kV | | EN 61000-4-6 HF conducted | 10 V |
|
| CPA approval |
| model number | 001US | | accuracy class | 3 | | maximum allowable error | - | | Q (min) | 0,5 m³/h | | Q (t) | - | | Q (max) | 3 m³/h |
|
| Shock resistance |
| DIN IEC 68-2-27 | 20 g (11 ms) |
|
| Vibration resistance |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
|
| MTTF |
175 |
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight |
1551.5 |
| Housing |
rectangular |
| Dimensions |
110 x 100 x 80.5 |
| Material |
housing: AlMgSi0.5 anodized; sealing: FKM; PA 6.6; cover film: PA |
| Materials (wetted parts) |
Pipe section: stainless steel (1.4404 / 316L); Process connection sealing: NBR fiber-reinforced Gasket; FKM; PES |
| Process connection |
threaded connection G 3/4 external thread flat seal |
| Display |
| Display unit | 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) | | Switching status | 2 x LED, yellow | | Measured values | alphanumeric display, 4-digit | | Programming | alphanumeric display, 4-digit |
|
| Items supplied |
|
| Accessories (optional) |
| adapter for pipe: 1 x R1/2, stainless steel, E40178 | | adapter for pipe: 1 x R1/2, brass, E40151 |
|
| Remarks |
| MW = Measured value | | MEW = Final value of the measuring range | | sealing: only with supplied Centellen seals |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |