Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

PN7299 – фото
Фото
Видео

На PN7299

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Output signal switching signal; IO-Link; (configurable)
Measuring range -29.4...29.4
Medium temperature -25...80
Electrical design PNP/NPN
Process connection 1/4" NPT Internal thread

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range <table><tr><td>-1...1 bar</td><td>-1000...1000 mbar</td><td>-14.5...14.5 psi</td><td>-29.4...29.4 inHg</td><td>-100...100 kPa</td></tr></table>
Process connection threaded connection 1/4" NPT Internal thread
Application
System gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Medium temperature -25...80
Min. bursting pressure <table><tr><td>30000 mbar</td><td>450 psi</td><td>880 inHg</td><td>3000 kPa</td></tr></table>
Pressure rating <table><tr><td>10000 mbar</td><td>145 psi</td><td>290 inHg</td><td>1000 kPa</td></tr></table>
Type of pressure relative pressure; vacuum
MAWP (for applications according to CRN) <table><tr><td>20 bar</td><td>20000 mbar</td><td>290 psi</td><td>590.59 inHg</td><td>2000 kPa</td></tr></table>
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption < 35
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time < 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC < 170
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>-1...1 bar</td><td>-1000...1000 mbar</td><td>-14.5...14.5 psi</td><td>-29.4...29.4 inHg</td><td>-100...100 kPa</td></tr></table>
Factory setting / CMPT = 2
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr><tr><td>Function</td><td>Device diagnosis</td></tr></table>
Min. process cycle time 2.3
IO-Link resolution pressure <table><tr><td>1 mbar</td><td>0.001 MPa</td></tr></table>
IO-Link process data (cyclical) <table><tr><th>Function</th><th>bit length</th></tr><tr><td>pressure</td><td>14</td></tr><tr><td>binary switching information</td><td>2</td></tr></table>
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles <table><tr><td>Smart Sensor - SSP 3.1</td><td>Measuring Sensor</td></tr><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr></table>
Min. process cycle time 3
IO-Link resolution pressure <table><tr><td>1 mbar</td><td>0.001 MPa</td></tr></table>
IO-Link process data (cyclical) <table><tr><th>Function</th><th>bit length</th></tr><tr><td>pressure</td><td>16</td></tr><tr><td>device status</td><td>4</td></tr><tr><td>binary switching information</td><td>2</td></tr></table>
IO-Link functions (acyclical) application specific tag
Accuracy / deviations
Switch point accuracy < ± 0,5
Repeatability < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation < ± 0,25
Long-term stability < ± 0,05; (per 6 months)
Temperature coefficient zero point < ± 0,2; (-0...80 °C)
Temperature coefficient span < ± 0,2; (-0...80 °C)
Reaction times
Response time < 3
Delay time programmable dS, dr 0...50
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port class A; (when pin 2 not connected: B)
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>Factory setting / CMPT = 2</td><td>457</td></tr><tr><td>Status_B High Resolution / CMPT = 3</td><td>636</td></tr></table>
Note <table><tr><td> For further information please see the IODD PDF file at "Downloads"</td></tr></table>
Operating conditions
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN EN 60068-2-27</td><td>50 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN EN 60068-2-6</td><td>20 g (10...2000 Hz)</td></tr></table>
MTTF 260
UL approval <table><tr><td>UL approval number</td><td>J001 </td></tr></table>
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 221.5
Housing tubular
Dimensions Ø 34 / L = 90.7
Material stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (1.4404 / 316L); ceramics; FKM
Min. pressure cycles 100 million
Tightening torque 2...3 turns after hand-fastening; recommended tightening torque; Depends on lubrication, seal and pressure rating
Process connection threaded connection 1/4" NPT Internal thread
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display <table><tr><td>Display unit</td><td>4 x LED, green (bar, psi, kPa, inHg)</td></tr><tr><td>Switching status</td><td>2 x LED, yellow</td></tr><tr><td>Measured values</td><td>alphanumeric display, red/green 4-digit</td></tr></table>
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

Two switching outputs, one of them with IO-Link communication interface
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link