Найти
Телефон
Меню

Официальный представитель завода АО «Таурас-Феникс»

в Уфе, в Казани, в Оренбурге, в Перми, в Ижевске и в Казахстане

Taures-fenix
+7 347 201 77 10 Бесплатно по России

TA2313 – фото
TA2313 – фото
TA2313 – фото
Фото
Видео

На TA2313

Для заявки пишите в МАХ или Telegram

# #

Характеристики

Pressure rating 300
Factory setting 0...300 °F
Measuring range temperature -58...302 °F
Installation length EL 50
Process connection 1/2" NPT external thread

Все характеристики

Product characteristics
Number of inputs and outputs Number of analog outputs: 1
Measuring range -58...302
Communication interface IO-Link
Process connection threaded connection 1/2" NPT external thread
Installation length EL 50
Application
System gold-plated contacts
Measuring element 1 x Pt 1000; (to DIN EN 60751, class A)
Media liquids and gases
Pressure rating <table><tr><td>300 bar</td><td>30 MPa</td></tr></table>
Note on pressure rating <table><tr><td> sensor</td></tr><tr><td> When mounted in adapters the specifications of the adapter data sheet apply.</td></tr></table>
MAWP (for applications according to CRN) 300
Electrical data
Operating voltage 18...32 DC; (cULus - Class 2 source required)
Current consumption < 50
Protection class III
Reverse polarity protection yes
Power-on delay time 1
Inputs / outputs
Number of inputs and outputs Number of analog outputs: 1
Outputs
Total number of outputs 1
Output signal analog signal; IO-Link; (configurable)
Number of analog outputs 1
Analog current output 4...20
Max. load 250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protection yes
Overload protection yes
Measuring/setting range
Probe length L 46.8
Measuring range -58...302
Factory setting 0...300 °F
Resolution
Resolution of analog output 0.04
Accuracy / deviations
Precision analog output ± 0,3 + (± 0,1 % MS)
Temperature coefficient 0,1; (In case of deviation from the reference condition 25 ± 5 °C)
Reaction times
Dynamic response T05 / T09 1 / 3
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr></table>
Min. process cycle time 2.3
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>378</td></tr></table>
Operating conditions
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC <table><tr><td>DIN EN 61000-6-2</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN IEC 68-2-27</td><td>50 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN IEC 68-2-6</td><td>20 g (10...2000 Hz)</td></tr></table>
MTTF 572
UL approval <table><tr><td>UL approval number</td><td>K002 </td></tr></table>
Mechanical data
Weight 132.5
Housing tubular
Dimensions Ø 18.7 / L = 125.7
Material stainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts) stainless steel (1.4404 / 316L)
Process connection threaded connection 1/2" NPT external thread
Probe diameter 6
Installation length EL 50
Displays / operating elements
Display <table><tr><td>operating status</td><td>1 x LED, green</td></tr></table>
Remarks
Remarks <table><tr><td>MS = set measuring span</td></tr></table>
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Приемущества

High precision across the entire temperature measurement range
Fast response dynamics and very short power-on delay time
Robust stainless steel housing with high pressure resistance
High protection rating for the requirements of harsh industrial environments
Precise analog output and user-friendly communication via IO-Link