Характеристики

Pressure rating 160
Factory setting 0...100 °C
Measuring range temperature -50...200 °C
Installation length EL 100
Process connection G 1/2 external thread sealing cone

Все характеристики

Product characteristics
Number of inputs and outputs Number of analog outputs: 1
Measuring range -50...200
Communication interface IO-Link
Process connection threaded connection G 1/2 external thread sealing cone
Installation length EL 100
Application
Measuring element 1 x Pt 1000; (to DIN EN 60751, class A)
Media liquids and gases
Pressure rating <table><tr><td>160 bar</td><td>16 MPa</td></tr></table>
Vacuum resistance <table><tr><td>-1000 mbar</td><td>-0.1 MPa</td></tr></table>
MAWP (for applications according to CRN) 160
Electrical data
Operating voltage 18...32 DC; (cULus - Class 2 source required)
Current consumption < 50
Protection class III
Reverse polarity protection yes
Power-on delay time 2
Inputs / outputs
Number of inputs and outputs Number of analog outputs: 1
Outputs
Total number of outputs 1
Output signal analog signal; IO-Link; (configurable)
Number of analog outputs 1
Analog current output 4...20
Max. load 250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protection yes
Overload protection yes
Measuring/setting range
Probe length L 100
Measuring range -50...200
Factory setting 0...100 °C
Resolution
Resolution of analog output 0.04
Accuracy / deviations
Precision analog output ± 0,3 + (± 0,1 % MS)
Temperature coefficient 0,1; (In case of deviation from the reference condition 25 ± 5 °C)
Reaction times
Dynamic response T05 / T09 < 0,5 / < 2
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
Profiles <table><tr><td>Smart Sensor - SSP 0</td><td>Generic Profiled Sensor</td></tr><tr><td>Function</td><td>Device identification</td></tr><tr><td>Function</td><td>Process data variable</td></tr></table>
Min. process cycle time 2.3
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>848</td></tr></table>
Operating conditions
Ambient temperature -25...80
Note on ambient temperature <table><tr><td>at medium temperature: < 160 °C</td></tr><tr><td> -25...60 °C</td></tr><tr><td>at medium temperature: < 200 °C</td></tr></table>
Storage temperature -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC <table><tr><td>DIN EN 61000-6-2</td><td></td></tr><tr><td>DIN EN 61000-6-3</td><td></td></tr></table>
Shock resistance <table><tr><td>DIN IEC 68-2-27</td><td>50 g (11 ms)</td></tr></table>
Vibration resistance <table><tr><td>DIN IEC 68-2-6</td><td>10 g (10...2000 Hz)</td></tr></table>
MTTF 334
Note on approval <table><tr><td> Factory certificate available as download at www.factory-certificate.ifm</td></tr></table>
UL approval <table><tr><td>UL approval number</td><td>K002 </td></tr></table>
Mechanical data
Weight 230
Housing tubular
Dimensions Ø 18.7 / L = 198.8
Material stainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts) stainless steel (1.4404 / 316L) electropolished
Tightening torque 30...50
Process connection threaded connection G 1/2 external thread sealing cone
Surface characteristics Ra/Rz of the wetted parts Ra < 0.8 µm
Probe diameter 6
Installation length EL 100
Remarks
Remarks <table><tr><td>MS = set measuring span</td></tr><tr><td> The values for accuracy apply to flowing water.</td></tr></table>
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A

Приемущества

Hygienic design for the requirements of the food and beverage industry
Fast response dynamics and very short power-on delay time
High precision across the entire temperature measurement range
Robust stainless steel housing with high protection rating and high pressure resistance
User-friendly communication and parameterization via IO-Link