| Number of inputs and outputs |
Number of digital outputs: 2 |
| Measuring range |
| -100...600 °C | -148...1112 °F |
|
| Communication interface |
IO-Link |
| Process connection |
threaded connection G 1/2 external thread |
| System |
gold-plated contacts |
| Application |
for Pt100 and Pt1000 measuring elements |
| Operating voltage |
18...32 DC; (cULus - Class 2 source required) |
| Current consumption |
< 50 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
1 |
| Integrated watchdog |
yes |
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Total number of outputs |
2 |
| Output signal |
switching signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC |
2.5 |
| Permanent current rating of switching output DC |
250 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring range |
| -100...600 °C | -148...1112 °F |
|
| Set point SP |
| -99.8...600 °C | -147.6...1112 °F |
|
| Reset point rP |
| -100...599.8 °C | -148...1111.6 °F |
|
| In steps of |
|
| Resolution of switching output |
0.1 |
| Resolution of display |
0.1 |
| Switch point accuracy |
± 0,3 + (± 0,1 % MS) |
| Display accuracy |
± 0,3 + (± 0,1 % MS) |
| Temperature coefficient |
0,1; (In case of deviation from the reference condition 25 ± 5 °C) |
| Response time |
390 |
| Parameter setting options |
hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| Profiles |
| Smart Sensor - SSP 0 | Generic Profiled Sensor | | Function | Device identification | | Function | Process data variable | | Function | Device diagnosis |
|
| Min. process cycle time |
2.3 |
| Supported DeviceIDs |
| Type of operation | DeviceID |
|---|
| default | 585 |
|
| Ambient temperature |
-25...80 |
| Storage temperature |
-40...100 |
| Protection |
IP 67 |
| EMC |
| DIN EN 61000-6-3 | | | DIN EN 61000-6-2 | |
|
| Shock resistance |
| DIN IEC 68-2-27 | 50 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
| MTTF |
252 |
| UL approval |
|
| Weight |
198.5 |
| Housing |
tubular |
| Dimensions |
Ø 34 / L = 104 |
| Material |
stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PBT+PC-GF30; PBT-GF20; PC |
| Process connection |
threaded connection G 1/2 external thread |
| Display |
| Display unit | 2 x LED, green | | Switching status | 2 x LED, yellow | | Measured values | alphanumeric display, red/green 4-digit |
|
| Remarks |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |