Характеристики

Protection IP 65, IP 67
Approval cULus, CE, CRN, UKCA

Все характеристики

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range <table><tr><td>0.8...83.4 l/min</td><td>0.3...27.6 m/s</td><td>0.05...5 m³/h</td></tr></table>
Process connection threaded connection G 1/4 Internal thread DN8
Application
Application for industrial applications
Media helium
Medium temperature -10...60
Min. bursting pressure 64
Pressure rating <table><tr><td>16 bar</td><td>1.6 MPa</td></tr></table>
MAWP (for applications according to CRN) 9.5
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption < 80
Protection class III
Reverse polarity protection yes
Power-on delay time 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Inputs
Inputs counter reset
Outputs
Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC 2.5
Permanent current rating of switching output DC 150; (per output)
Number of analog outputs 1
Analog current output 4...20; (scalable)
Max. load 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range <table><tr><td>0.8...83.4 l/min</td><td>0.3...27.6 m/s</td><td>0.05...5 m³/h</td></tr></table>
Display range <table><tr><td>0...100 l/min</td><td>0...33.1 m/s</td><td>0...6 m³/h</td></tr></table>
Resolution <table><tr><td>0.2 l/min</td><td>0.1 m/s</td><td>0.01 m³/h</td></tr></table>
Set point SP <table><tr><td>1.3...83.3 l/min</td><td>0.4...27.6 m/s</td><td>0.08...5 m³/h</td></tr></table>
Reset point rP <table><tr><td>0.9...82.9 l/min</td><td>0.3...27.5 m/s</td><td>0.05...4.97 m³/h</td></tr></table>
Analog start point ASP <table><tr><td>0...66.6 l/min</td><td>0...22.1 m/s</td><td>0...4 m³/h</td></tr></table>
Analog end point AEP <table><tr><td>16.7...83.3 l/min</td><td>5.5...27.6 m/s</td><td>1...5 m³/h</td></tr></table>
Low flow cut-off LFC <table><tr><td>0.6...0.8 l/min</td><td>0.2...0.3 m/s</td><td>0.04...0.05 m³/h</td></tr></table>
In steps of <table><tr><td>0.1 l/min</td><td>0.1 m/s</td><td>0.01 m³/h</td></tr></table>
Pressure monitoring
Response time 0.05
Volumetric flow quantity monitoring
Measuring range <table><tr><td>0...100000000 m³</td><td>0...353146667.2 scf</td></tr></table>
Display range <table><tr><td>0...100000000 m³</td><td>0...353146667.2 scf</td></tr></table>
Set point SP <table><tr><td>0.001...10000000 m³</td><td>0.05...353146667.2 scf</td></tr></table>
Pulse value <table><tr><td>0.001...10000000 m³</td><td>0.05...353146667.2 scf</td></tr></table>
In steps of <table><tr><td>0.0001 m³</td><td>0.005 scf</td></tr></table>
Pulse length 0.01...2
Temperature monitoring
Dynamic response T05 / T09 T09 = 0,5
Accuracy / deviations
Temperature coefficient ± 0,07 % MW
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); at medium temperature 23 °C
Repeatability 0,8 % MW + 0,2 % MEW
Reaction times
Response time 0.1; (dAP = 0)
Damping process value dAP 0...5
Software / programming
Parameter setting options hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles <table><tr><td>Common - I&D</td><td>Identification and Diagnosis</td></tr><tr><td>Function</td><td>Measurement data, standard resolution</td></tr></table>
SIO mode yes
Required master port class A
Process data analog 8
Process data binary 2
Min. process cycle time 7.2
Supported DeviceIDs <table><tr><th>Type of operation</th><th>DeviceID</th></tr><tr><td>default</td><td>1301</td></tr></table>
Operating conditions
Ambient temperature 0...60
Storage temperature -20...85
Max. relative air humidity 90
Protection IP 65; IP 67
Tests / approvals
EMC <table><tr><td>DIN EN 60947-5-9</td><td></td></tr></table>
CPA approval <table><tr><td>model number</td><td>003TG</td></tr><tr><td>accuracy class</td><td>-</td></tr><tr><td>maximum allowable error</td><td>± 7 % FS</td></tr><tr><td>Q (min)</td><td>0,05 m³/h (He)</td></tr><tr><td>Q (t)</td><td>-</td></tr><tr><td>Q (max)</td><td
Vibration resistance <table><tr><td>DIN EN 68000-2-6</td><td>5 g (10...2000 Hz)</td></tr></table>
MTTF 180
UL approval <table><tr><td>UL approval number</td><td>I012 </td></tr><tr><td>File number UL</td><td>E174189 </td></tr></table>
Pressure equipment directive sound engineering practice; can be used for stable gases fluid group 2
Mechanical data
Weight 554
Housing rectangular
Dimensions 182 x 45.4 x 67.8
Material PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
Materials (wetted parts) EN AW-6082 (aluminium); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connection threaded connection G 1/4 Internal thread DN8
Displays / operating elements
Display <table><tr><td></td><td>Color display 1,44", 128 x 128 pixels</td></tr><tr><td></td><td>2 x LED, yellow</td></tr></table>
Remarks
Remarks <table><tr><td>MW = Measured value</td></tr><tr><td>MEW = Final value of the measuring range</td></tr><tr><td> Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity</td></tr><tr><td> For information about installation and operation please see
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A

Приемущества

Precise measurement of flow, consumption, pressure and medium temperature
High accuracy, repeatability and measurement dynamics
For the detection of helium
Red/green display for clear identification of the acceptable range
Display can be rotated for optimum alignment
Convenient operation via buttons or parameter setting via IO-Link